Email :ceo@zbyuhai.com Tel : +8618753397607
Contact us
Zibo Yuhai Electronic Ceramic Co., Ltd.
Address : No.57 Chuangye Road, Development Area Boshan, Zibo City, Shandong Prov. P.R. of China
Tel : +86-0533-4230012
Fax : +86-0533-4231700
Email : sales@zbyuhai.com
Piezoelectric tube-Φ28×Φ25×40mm
Piezoelectric ceramic tubes
Electrode direction: Radial direction
Applications: NDT Non destructive Testing
Non-destructive testing (NDT) is a testing method to inspect the surface and internal quality of the inspected parts without damaging the working state of the workpiece or raw materials.
There are many kinds of ultrasonic flaw detectors, but in the actual flaw detection process, pulse reflection ultrasonic flaw detectors are most widely used. Generally, in homogeneous materials, the existence of defects will cause the discontinuity of materials, which often results in the inconsistency of acoustic impedance. From the reflection theorem, we know that ultrasound will reflect at the interface of two media with different acoustic impedance. The magnitude of the reflected energy is related to the difference of acoustic impedance of the media on both sides of the interface and the orientation and size of the interface.
Material: PZT-52( HD PZT-5A)
Technical data:
Dimensions: OD 28mm, ID25mm, height 40mm
Radial Frequency Fr: 34KHz ± 5%
Frequency Bandwidth ΔF>300Hz
Resonant Impedence (Ω)<100
Dielectric Loss tg δ: <2.20
Static capacitance Cs: 47nF±20%
Test Condition: 25±3 °C 40~70% R.H.
fr, Zm, Kr => Radial mode vibration
Cs tanδ => LCR meter at 1KHz 1Vrms
SOFT PZT suitable for NDT detector.
Typical value of piezoelectric ceramic materials performance | |||||||||
"Soft" PZT materials | |||||||||
Properties | PZT-51 | PZT-52 | PZT-53 | PZT-5H | PLiS-51 | PMgN-51 | PSnN-5 | ||
Dielectric Constant | ɛTr3 | 2200 | 2400 | 2600 | 3200 | 2000 | 3800 | 1600 | |
Coupling factor | KP | 0.62 | 0.63 | 0.64 | 0.68 | 0.62 | 0.64 | 0.6 | |
K31 | 0.35 | 0.35 | 0.36 | 0.38 | 0.35 | 0.35 | 0.35 | ||
K33 | 0.68 | 0.7 | 0.7 | 0.76 | 0.7 | 0.7 | 0.68 | ||
Kt | 0.5 | 0.5 | 0.5 | 0.52 | 0.52 | 0.52 | 0.5 | ||
Piezoelectric coefficient | d31 | 10-12m/v | -186 | -204 | -227 | -275 | -197 | -270 | -170 |
d33 | 10-12m/v | 500 | 520 | 550 | 620 | 450 | 600 | 400 | |
g31 | 10-3vm/n | -9.6 | -9.8 | -9.9 | -9.7 | -11.1 | -8 | -12 | |
g33 | 10-3vm/n | 25.6 | 24.5 | 23.9 | 22 | 25.4 | 18 | 28 | |
Frequency coefficients | Np | 1980 | 1980 | 1960 | 1900 | 1920 | 1980 | 2000 | |
N1 | 1451 | 1451 | 1437 | 1393 | 1407 | 1451 | 1466 | ||
N3 | 1900 | 1900 | 1755 | 1550 | 1925 | 1800 | 1825 | ||
Nt | 2150 | 2150 | 2150 | 2100 | 2100 | 2100 | 2100 | ||
Elastic compliance coefficient | Se11 | 10-12m2/n | 16.7 | 17 | 17.4 | 18 | 18 | 18 | 16.6 |
Machanical quality factor | Qm | 80 | 75 | 75 | 70 | 80 | 70 | 85 | |
Dielectric loss factor | Tg δ | % | 2 | 2 | 2 | 2 | 2 | 1.8 | 2 |
Density | ρ | g/cm3 | 7.6 | 7.6 | 7.6 | 7.5 | 7.5 | 7.6 | 7.5 |
Curie Temperature | Tc | °C | 270 | 270 | 270 | 230 | 345 | 270 | 350 |
Young's modulus | YE11 | <109N/m2 | 60 | 59 | 57.5 | 56 | 56 | 56 | 60 |
Poison Ratio | 0.36 | 0.36 | 0.36 | 0.36 | 0.36 | 0.36 | 0.36 |